Total vulnerabilities in the database
miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request.
Software | From | Fixed in |
---|---|---|
siemens / wincc_flexible | 2004 | 2004.x |
siemens / wincc_flexible | 2008 | 2008.x |
siemens / wincc_flexible | 2008-sp1 | 2008-sp1.x |
siemens / wincc_flexible | 2008-sp2 | 2008-sp2.x |
siemens / wincc_flexible | 2007 | 2007.x |
siemens / wincc_flexible | 2005 | 2005.x |
siemens / wincc | 11 | 11.x |
siemens / wincc | 11-sp1 | 11-sp1.x |
siemens / wincc | - | 11.x |
siemens / simatic_hmi_panels | tp | tp.x |
siemens / simatic_hmi_panels | op | op.x |
siemens / simatic_hmi_panels | mobile_panels | mobile_panels.x |
siemens / simatic_hmi_panels | comfort_panels | comfort_panels.x |
siemens / simatic_hmi_panels | mp | mp.x |
siemens / wincc_runtime_advanced | 11 | 11.x |
siemens / wincc_flexible_runtime | - | - |