Total vulnerabilities in the database
BIND 9.16.11 -> 9.16.26, 9.17.0 -> 9.18.0 and versions 9.16.11-S1 -> 9.16.26-S1 of the BIND Supported Preview Edition. Specifically crafted TCP streams can cause connections to BIND to remain in CLOSE_WAIT status for an indefinite period of time, even after the client has terminated the connection.
Software | From | Fixed in |
---|---|---|
isc / bind | 9.17.0 | 9.18.0.x |
isc / bind | 9.16.11 | 9.16.27 |
fedoraproject / fedora | 34 | 34.x |
fedoraproject / fedora | 35 | 35.x |
fedoraproject / fedora | 36 | 36.x |
siemens / sinec_ins | 1.0-sp1 | 1.0-sp1.x |
siemens / sinec_ins | - | 1.0 |
siemens / sinec_ins | 1.0 | 1.0.x |