Total vulnerabilities in the database
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions < V3.0.37), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SINAMICS S210 (6SL5...) (All versions >= V6.1 < V6.1 HF2), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions < V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used.
An attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product.
Software | From | Fixed in |
---|---|---|
siemens / sinamics_s210_firmware | 5.1-sp1_hotfix8 | 5.1-sp1_hotfix8.x |
siemens / sinamics_s210_firmware | 5.1 | 5.1.x |
siemens / sinamics_s210_firmware | 5.1-sp1 | 5.1-sp1.x |
siemens / sinamics_s210_firmware | 5.2-sp3_hotfix5 | 5.2-sp3_hotfix5.x |
siemens / sinamics_s210_firmware | 5.2-sp3_hotfix3 | 5.2-sp3_hotfix3.x |
siemens / sinamics_s210_firmware | 5.2-hotfix6 | 5.2-hotfix6.x |
siemens / sinamics_s210_firmware | 5.2-sp3_hotfix9 | 5.2-sp3_hotfix9.x |
siemens / sinamics_s210_firmware | 5.2-sp3 | 5.2-sp3.x |
siemens / sinamics_s210_firmware | 5.2-sp3_hotfix6 | 5.2-sp3_hotfix6.x |
siemens / sinamics_s210_firmware | 5.2 | 5.2.x |
siemens / sinamics_s210_firmware | 5.2-hotfix5 | 5.2-hotfix5.x |
siemens / sinamics_s210_firmware | 5.2-hotfix2 | 5.2-hotfix2.x |
siemens / sinamics_s210_firmware | 5.2-hotfix7 | 5.2-hotfix7.x |
siemens / sinamics_s210_firmware | 6.1 | 6.1.x |
siemens / sinamics_s210_firmware | 6.1-hotfix1 | 6.1-hotfix1.x |